羅茨鼓風機標準化啟停操作規程與技術要點

來源:http://www.liujianlin.cn/ 發布時間:日期:2025-05-19 1

  羅茨鼓風機作為容積式氣體輸送設備的典型代表,其啟停操作直接影響設備壽命與運行穩定性。本文從技術規范角度,系統闡述標準化操作流程與關鍵注意事項。

  As a typical representative of volumetric gas conveying equipment, the start stop operation of Roots blower directly affects the service life and operational stability of the equipment. This article systematically elaborates on standardized operating procedures and key considerations from the perspective of technical specifications.

  一、啟動前準備與安全檢查

  1、 Preparation and safety check before startup

  機械狀態確認

  Mechanical status confirmation

  檢查地腳螺栓、聯軸器護罩等緊固件是否完好,手動盤車確認轉子旋轉無卡滯,軸承游隙符合設備手冊要求。

  Check whether the anchor bolts, coupling guards, and other fasteners are intact, manually rotate the rotor to confirm that there is no jamming, and the bearing clearance meets the requirements of the equipment manual.

  確認潤滑系統油位處于視窗1/2至2/3區間,油品粘度等級符合環境溫度要求,北方冬季需采用低溫潤滑脂。

  Confirm that the oil level of the lubrication system is within the range of 1/2 to 2/3 of the window, and that the viscosity grade of the oil meets the requirements of the ambient temperature. Low temperature grease should be used in winter in northern China.

  管路系統核查

  Pipeline system verification

  排氣閥門應處于全開狀態,避免帶壓啟動對齒輪箱造成沖擊。旁通管路需保持暢通,作為緊急泄壓通道。

  The exhaust valve should be fully open to avoid impact on the gearbox caused by pressure starting. The bypass pipeline needs to be kept unobstructed as an emergency pressure relief channel.

  進口消音器濾網清潔度達標,阻力值≤500Pa,必要時采用壓縮空氣反向吹掃。

  The cleanliness of the imported muffler filter meets the standard, with a resistance value of ≤ 500Pa. If necessary, compressed air can be used for reverse blowing.

  電氣聯鎖校驗

  Electrical interlocking verification

  確認電機轉向與設備標示一致,通過點動測試驗證旋轉方向,反轉會導致轉子瞬間碰撞。

  Confirm that the motor direction is consistent with the equipment label, verify the rotation direction through jog testing, and reverse rotation will cause instantaneous collision of the rotor.

  檢查過載保護裝置設定值,電流閾值應為額定電流的1.1-1.2倍,避免頻繁跳閘。

  Check the setting value of the overload protection device, and the current threshold should be 1.1-1.2 times the rated current to avoid frequent tripping.

  二、標準化啟動流程

  2、 Standardized initiation process

  空載預熱階段

  No load preheating stage

  啟動潤滑油泵,循環10-15分鐘,確保軸承箱與齒輪嚙合面形成穩定油膜。觀察油溫變化,冬季需配置加熱器維持油溫≥15℃。

  Start the lubricating oil pump and cycle for 10-15 minutes to ensure a stable oil film is formed between the bearing housing and the gear meshing surface. Observe changes in oil temperature, and in winter, a heater should be installed to maintain an oil temperature of ≥ 15 ℃.

  漸進加載程序

  Progressive loading program

  關閉旁通閥,以20%間隔逐步調節進氣閥開度,每次調整間隔3-5分鐘,使轉子逐步適應載荷變化。

  Close the bypass valve and gradually adjust the opening of the intake valve at 20% intervals, with a 3-5 minute interval between each adjustment, to gradually adapt the rotor to changes in load.

  監控軸振動速度有效值,≤4.5mm/s為正常范圍,超過6.0mm/s需緊急停機檢查。

  The effective value of the monitoring shaft vibration speed is ≤ 4.5mm/s, which is within the normal range. If it exceeds 6.0mm/s, an emergency stop inspection is required.

  工況參數整定

  Setting of working condition parameters

  待出口壓力穩定后,調節安全閥開啟壓力至額定工作壓力的1.05-1.1倍,形成雙重保護機制。

  After the outlet pressure is stable, adjust the opening pressure of the safety valve to 1.05-1.1 times the rated working pressure to form a dual protection mechanism.

  校驗壓力表、溫度傳感器精度,誤差范圍應符合GB/T 12242標準要求。

  Verify the accuracy of pressure gauges and temperature sensors, and ensure that the error range meets the requirements of GB/T 12242 standard.

  三、正常停機操作規范

  3、 Normal shutdown operation specifications

  卸荷停機程序

  Unloading shutdown program

  逐步開啟旁通閥,以30%間隔分階段卸載,每次調整間隔不少于5分鐘,避免壓力突變導致轉子反向沖擊。

  Gradually open the bypass valve and unload in stages at 30% intervals, with each adjustment interval not less than 5 minutes, to avoid sudden pressure changes that may cause rotor reverse impact.

  關閉進氣閥,待電流降至空載值后執行斷電操作,禁止帶壓停機。

  Close the intake valve and perform a power-off operation after the current drops to the no-load value. Do not shut down under pressure.

  后處理與防護

  Post processing and protection

  停機后持續運轉潤滑系統20-30分鐘,防止高溫油品碳化。軸承箱溫度降至40℃以下方可停泵。

  Run the lubrication system continuously for 20-30 minutes after shutdown to prevent carbonization of high-temperature oil products. The pump can only be stopped when the temperature of the bearing box drops below 40 ℃.

  南方潮濕環境需定期盤車,每24小時旋轉180°,避免轉子軸系變形。

  The humid environment in the south requires regular turning, rotating 180 ° every 24 hours to avoid deformation of the rotor shaft system.

  四、特殊工況處置方案

  4、 Special working condition disposal plan

  喘振預防措施

  Surge prevention measures

  當出口壓力波動幅度超過額定值的20%時,立即開啟旁通管路泄壓,同步檢查管路阻力特性。

  When the fluctuation amplitude of the outlet pressure exceeds 20% of the rated value, immediately open the bypass pipeline to release pressure and synchronously check the resistance characteristics of the pipeline.

  調整導葉開度,使工作點遠離喘振邊界線,安全裕度≥15%。

  Adjust the opening of the guide vanes to keep the working point away from the surge boundary line, with a safety margin of ≥ 15%.

21

  高溫應急處理

  High temperature emergency response

  軸承溫度超過85℃時,檢查冷卻水流量是否達標,必要時切換備用冷卻回路。

  When the bearing temperature exceeds 85 ℃, check whether the cooling water flow meets the standard, and switch to the backup cooling circuit if necessary.

  潤滑油溫過高需啟用油冷卻器,確保油品粘度不低于ISO VG 32標準。

  If the lubricating oil temperature is too high, an oil cooler should be activated to ensure that the viscosity of the oil is not lower than the ISO VG 32 standard.

  五、維護保養關鍵節點

  5、 Key maintenance milestones

  周期性檢測項目

  Periodic testing items

  每運行2000小時進行轉子間隙檢測,軸向間隙應≤0.15mm,徑向間隙≤0.30mm,超標需返廠維修。

  Perform rotor clearance testing every 2000 hours of operation, with axial clearance ≤ 0.15mm and radial clearance ≤ 0.30mm. If it exceeds the standard, it needs to be returned to the factory for repair.

  同步齒輪嚙合間隙每半年校驗一次,側隙標準值為0.25-0.35mm。

  The meshing clearance of synchronous gears is verified every six months, and the standard value of side clearance is 0.25-0.35mm.

  易損件更換周期

  Replacement cycle of vulnerable parts

  空氣濾芯每運行500小時清潔,1500小時更換,阻力超過1kPa必須更換。

  The air filter should be cleaned every 500 hours of operation and replaced after 1500 hours. If the resistance exceeds 1kPa, it must be replaced.

  軸封件累計運行4000小時更換,泄漏量超過5mL/h時提前更換。

  Replace the shaft seal after a cumulative operation of 4000 hours, and replace it in advance when the leakage exceeds 5mL/h.

  羅茨鼓風機的標準化啟停操作是保障設備可靠運行的基礎,需嚴格遵循操作規程并建立設備健康檔案。通過實施預防性維護策略,可顯著延長設備使用壽命,降低非計劃停機風險。

  The standardized start stop operation of Roots blowers is the foundation for ensuring reliable operation of equipment, and it is necessary to strictly follow the operating procedures and establish equipment health records. By implementing preventive maintenance strategies, the service life of equipment can be significantly extended and the risk of unplanned downtime can be reduced.

  本文由高壓羅茨鼓風機友情奉獻.更多有關的知識請點擊:http://www.liujianlin.cn我們將會對您提出的疑問進行詳細的解答,歡迎您登錄網站留言.

  This article is a friendly contribution from the pneumatic conveying system For more information, please click: http://www.liujianlin.cn We will provide detailed answers to your questions. You are welcome to log in to our website and leave a message

相關產品 / Related products

  • 氣動雙插板閥

    氣動雙插板閥

  • 氣動雙插板閥

    氣動雙插板閥

  • 氣動雙插板閥

    氣動雙插板閥

  • 氣動擺動閥

    氣動擺動閥

2024  濟南鑫魯泉盛機械設備有限公司     備案號:魯ICP備18012408號-3  魯公網安備37018102000806號

主站蜘蛛池模板: 国产精品亚洲精品观看不卡 | v片在线免费观看 | 精品偷自拍另类在线观看 | 男女性免费视频观看 | 亚洲欧美成人永久第一网站 | 青青自拍视频一区二区三区 | www.艹| 免费看黄色的网址 | 久久中文字幕不卡一二区 | 亚洲成人影院在线 | 亚洲成人高清在线 | 一级做性色a爰片久久毛片免费 | 久久精品无码一区二区日韩av | 欧美在线一级片 | videos雌雄同体xxxx视频 | 亚州免费视频 | 欧美一区二区三区不卡 | 免费看欧美毛片大片免费看 | 亚洲成人免费视频在线 | 欧美jizz18| 国内老司机精品视频在线播出 | 亚洲三级大片 | 黄站在线 | 无码中文av有码中文av | 国产成人精品免费视频网页大全 | 又粗又大又爽 真人一级毛片 | 日韩欧美中文字幕出 | 国产美女网站视频 | 欧洲妇女成人淫片aaa视频 | 一本久道久久综合中文字幕 | jizz自拍| 亚洲精品中文字幕乱码无线 | 国产精品网站在线观看 | 最近最新中文字幕8 | 欧美一级在线 | 性生交大片免费一级 | 波多野结衣久久国产精品 | 久久看视频 | 草的爽免费视频 | 日韩欧美区 | 亚洲欧美专区精品伊人久久 |